The unit is designed to simulate modern steam power plant. Main components consist of a feed water system, a small industrial boiler, a steam turbine, a generator and lamp load, a condenser with a condensate tank and a pump, and a cooling tower. Accessories such as fuel tank, fuel flow meter, feed water meter, and a stack are also included. Instruments are provided for measurement of pressures, temperatures, output voltage and current.
Instruction manual is also included.
- Measurement of feed water and fuel flow rates.
- Boiler efficiency, turbine generator efficiency, and overall power plant efficiency.
- Condenser heat transfer efficiency.
- Cooling tower efficiency. Rankine cycle efficiency.
The boiler set consists of:
A . Boiler Unit: | |
- Type | Vertical, water tube |
- Rated heat output | 188 kW (162,000 kcal/h) |
- Equivalent evaporation | Approx. 300 kg/h steam |
- Maximum working pressure | 10 kg/cm2 (0.98 MPa) |
- Measuring instruments |
|
- Safety devices |
|
- Boiler accessories |
|
Burner: | |
- Type | Forced draft, pressure atomized |
- Control | On-Off |
- Fuel | Diesel or kerosene (LPG is available as an option.) |
Fuel system | Stainless steel fuel tank, fuel strainer and fuel meter |
Feed water system: | |
- Resin filter for public water. | |
- Soft water tank. | Stainless steel |
- Water meter for steam rate monitoring | |
Power supply | 380 V, 3 Ph, 50Hz. Other power supply is available on request. |
B . Steam Turbine | |
- Type | Single stage, twin nozzle impulse turbine |
- Maximum electrical output | Approx. 0.9 kW |
Measuring instruments: | |
- Speed sensor for turbine | |
- Temperature sensors for steam inlet and outlet | |
- Pressure gauge for steam inlet | |
- Water manometer for turbine outlet |
C . Generator and Lamp Load | |
Voltage | 220V, 1 Ph, 50 Hz. |
Load lamps | 1 set. |
Measuring instruments |
D . Condenser and Cooling Tower | |
TH 102-013 |
Condenser Description : The unit allows a study of heat transfer in a heat exchanger as well as recover condensate for reuse. |
- Type | Steam tube |
- Accessories and instruments |
|
TH 137-014 |
Cooling Tower Description : This is an educational unit for recovering of condenser cooling water as well as studying of cooling tower efficiency. |
Part No. | Part Name |
---|---|
TH 101-021 | Sand filter for water with suspended materials |
TH 101-022 | Carbon filter for water with odour or rust |
TH 101-031 | Pressure digital display |
TH 101-032 | Fuel flow totalizer |
TH 101-033 | Feed water flow totalizer |
TH 101-035 | Cooling water flow digital display |
PH meter | |
TH 137-005EBA | Electric boiler instead diesel boiler |
TH 136-015 | Water Brake Dynamometer (HD160S) |
TH 137-020 |
Electric Super Heater Description : The unit provides superheated steam for other use such as for a stream turbine. Saturated steam from the boiler is further heated in the electric super heater. Instruments are provided for Measurement of temperature and pressure. The test is to be carried out at low steam rate and compare thermal efficiency for saturated and superheated steam. |
TH 137-050 |
Computer Interface Sensors with computer interface unit for key data acquisition instead of analog data measuring instruments. This comprises:
|
TH 137-060 |
Computer Control This comprises:
|
Other optional equipment please contact manufacturer (essom@essom.com) |
Shipping dimensions and weight | One 20 ft. containers |